Service Hotline: 0086-592-2229165
Products Products
Hot News / Hot News
2018 - 05 - 11
点击次数: 43
Hubgestelle von Schnupp für die Einarbeitung von Pressenwerkzeugen benötigen kein Fundament. Um die Projektlaufzeit bei vier aktuellen Maschinen zu verkürzen, simulierten die Konstrukte...
2018 - 03 - 25
点击次数: 35
Hannover/Istanbul. WIN EURASIA 2018, which ran from 15 to 18 March at the Tüyap Fair Convention and Congress Center in Istanbul, reunited for the first time in ten years six tradeshows at on...
2017 - 12 - 29
点击次数: 96
Network new and existing machines efficiently and make them transparent. The IoT Gateway software V2 from Bosch Rexroth achieves this with particular precision and cost-effectiveness.With many new fea...
2017 - 12 - 29
点击次数: 72
Although originally developed for other vehicle types, High Level Braking (HLB) is now also available for fork lift trucks.High Level Braking (HLB) saves installation space, reduces the complexity and...
2017 - 12 - 29
点击次数: 117
At SPS IPC Drives, Bosch Rexroth will present the complete spectrum of automation and electrification - from entry into the industrial IoT, to requirement-specific IPCs and intelligent drive solutions...
2017 - 12 - 29
点击次数: 81
Industry 4.0 would be inconceivable without software. The Connected Automation portfolio from Bosch Rexroth demonstrates its full potential in terms of connectivity and time-to-market.With innovations...
Contact us
联系我们
Phone: 0086-592-2229165 
Mailbox: info@sdmhyd.com
Address: Room 801 1st building No993 Anling Road Huli district, Xiamen City, Fujian Province, China  
Products 产品中心
产品列表
generalDirection of rotation (fan wheel)LeftInstallation positionhorizontal and verticalhydraulicOperating pressure max.bar26Hydraulic fluid 1)Mineral oil (HLP) according to DIN 51524, part 2Hydraulic fluid temperature range°C-20 … +80Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 2) 3)Class 21/19/16Viscosity rangemm²/s2.0001)Please observe our provisions according to data sheet 07075!2)The cleanliness classes specified for the components must be adhered to in the hydraulic system. Effective filtration prevents faults and at the same time increases the life cycle of the components.3)Does not apply to version KOLP.../R... and KOLP…/R-…F… (see table “Amending technical data…”)Air...
Technical dataLine connectionsOil sideConnection thread according to ISO 1179, pipe connections according to DIN 2353/ISO 8434, flanges according to ISO 6162Water sideThread according to ISO 228/1Type of pipingFitting according to DIN 2353; light/heavy seriesWith ABUKG-V: Precision steel pipes according to DIN 2391/C, DIN EN ISO 1127Hydraulic fluids 1)Mineral oil HLP46 according to DIN 51524, part 2Hydraulic fluid temperature range 2)°C 25 …  80Installation positionVerticalCoolantPotable, process, stream and river water (filtration recommended)Cooling water demand at least: VK=0.5 x Voil [l/min](min. 0.1 bar at the water valve)Heating (H2O):Δv=14 x power loss (kW)/VK [...
AccumulatorsDesignDiaphragm type accumulatorsInstallation positionAny, preferably with the fluid connection socket at the bottomAmbient temperature range°C-15 … +65Line connectionScrew-in threadHydraulic fluid 1)Hydraulic oil according to DIN 51524Hydraulic fluid temperature range 2)NBR diaphragm°C-10 … +80ECO diaphragm°C-35 … +80Acceptance specificationsCE/BAAcceptance according to 2014/68/EU or the operating instructionsChinaSELORussiaGOST1)Other hydraulic fluids upon request.2)Others on request.hydraulic, diaphragm type accumulatorNominal capacityVNennl0.71.422.83.5Effective gas volumeVeffl0.751.41.952.73.5Maximum admissible flowqmaxl/min4060Maximum admissible operating pressurepmaxbar350Maximum admissible pressure fluctuation ...
Set-up of the motor-pump groupDesign ABHPG▶ Pump▶ Electric motor▶ Pump carrier▶ Coupling▶ Pump baseUse of this design is recommended for restricted installation conditions (e.g. on oil tanks).Max. performance range 7.5 kW.STEP files of the relevant assembly upon request.Set-up of the motor-pump groupDesign ABAPG▶ Pump▶ Electric motor▶ Pump carrier▶ Coupling▶ Strips▶ Damping bearingUse of this design is particularly recommended for requirements on low noise levels.Min. performance range 5.5 kWSTEP files of the relevant assemblies upon request.Technical dataLine connectionssee table Line connectionsHydraulic fluid 1)Mineral oil HLP according to DIN 51524; part 2e.g. with operating temperature 50 °C ISO VG46 DIN ISO 3448Pump typeA10VSO10 series 52 according to da...
Technical dataHydraulic fluid 1)Mineral oil (HLP) to DIN 51524-2Hydraulic fluid temperature range°C-20 … +80Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 2)Class 20/18/15 according to ISO 4406 (c)Optimum viscosity rangemm²/s10 … 200Direction of rotationany (radial piston pump), clockwise (external gear pump)Installation positionVerticalOperating modeAll operating modes with which the steady-state oil temperature remains below 80 °C.Protection class according to VDE 0530/EN 60034IP54 with completely mounted power unitTank size3/R4/R4/G5/R7/R7/GWeight 3)kg17.818.419.6232526.61)Please observe our provisions according to data sheet 07075!2)The cl...
Technical dataLine connectionsOil sideConnection thread according to ISO 1179, pipe connections according to DIN 2353/ISO 8434, flanges according to ISO 6162Water connectionsPipe thread according to ISO 228/1Pump typeA10VSO 18 according to data sheet RE 92712A10VSO 28 … 140 according to data sheet RE 92711PVV 18 … 60 according to data sheet RE 10335Pump-motor groupABAPG according to data sheet R.51062Type of pipingFitting according to DIN 2353; light/heavy series; type WalformHydraulic fluid 1)Mineral oil (HL, HLP) according to DIN 51524; fast bio-degradable hydraulic fluids according to VDMA 24568 (see also RE 90221) HETG (rape seed oil); HEPG (polyglycols); HEES (synthetic esters)Hydraulic fluid temperature range 2)+0 …...
Power unit set-upPower units with/without air heat exchanger in 3 control variants:1Pressure limitation (pressure control unit)6Pressure limitation with 1 to 8 spaces for vertical stacking NG67Pressure limitation with 1 to 8 spaces for vertical stacking NG6 including accumulator charging circuitTechnical dataTank sizel204060Line connectionsConnection thread according to ISO 1179 (DIN 3852-2 form X) and/or pipe connections according to ISO 8434 part 1Hydraulic fluid 1)Mineral oil HLP according to DIN 51524; part 2e.g. with operating temperature 50 °C ISO VG46 DIN ISO 3448Return flow filter with filter element according to DIN 24550 according to data sheet 51424Containersl20406010TEN0040-H10XLA00-V2,2-M-R3…10TEN0063-H10XLA00-V2,2-M-R3…10TEN00...
7页次1/1HomePrev1NextEnd
回到顶部
Copyright ©2005 - 2017 Siedman (Xiamen)Hydraulic Technology Co;Ltd
犀牛云提供企业云服务