Service Hotline: 0086-592-2229165
Products Products
Hot News / Hot News
2018 - 05 - 11
点击次数: 43
Hubgestelle von Schnupp für die Einarbeitung von Pressenwerkzeugen benötigen kein Fundament. Um die Projektlaufzeit bei vier aktuellen Maschinen zu verkürzen, simulierten die Konstrukte...
2018 - 03 - 25
点击次数: 36
Hannover/Istanbul. WIN EURASIA 2018, which ran from 15 to 18 March at the Tüyap Fair Convention and Congress Center in Istanbul, reunited for the first time in ten years six tradeshows at on...
2017 - 12 - 29
点击次数: 102
Network new and existing machines efficiently and make them transparent. The IoT Gateway software V2 from Bosch Rexroth achieves this with particular precision and cost-effectiveness.With many new fea...
2017 - 12 - 29
点击次数: 73
Although originally developed for other vehicle types, High Level Braking (HLB) is now also available for fork lift trucks.High Level Braking (HLB) saves installation space, reduces the complexity and...
2017 - 12 - 29
点击次数: 118
At SPS IPC Drives, Bosch Rexroth will present the complete spectrum of automation and electrification - from entry into the industrial IoT, to requirement-specific IPCs and intelligent drive solutions...
2017 - 12 - 29
点击次数: 83
Industry 4.0 would be inconceivable without software. The Connected Automation portfolio from Bosch Rexroth demonstrates its full potential in terms of connectivity and time-to-market.With innovations...
Contact us
联系我们
Phone: 0086-592-2229165 
Mailbox: info@sdmhyd.com
Address: Room 801 1st building No993 Anling Road Huli district, Xiamen City, Fujian Province, China  
Products 产品中心
产品列表
For applications outside these parameters, please consult us!generalSize681015202530WeightSee dimensionsInstallation positionanyAmbient temperature rangeNBR seals°C-30 … +80FKM seals°C-15 … +80Minimum stability of the housing materialsHousing materials are to be selected so that there is sufficient safety for all imaginable operating conditions (e.g. with regard to pressure resistance, thread stripping strengths and tightening torques).hydraulicSize681015202530Maximum operating pressureInletbar400630400315Outletbar315Maximum flow (standard valves)See characteristic curvesHydraulic fluidsee tableHydraulic fluid temperature rangeNBR seals°C-30 … +80FKM seals°C-15 … +80Viscosity rangemm²/s10 … 800Maximum admissibl...
generalSize10162532DB.. 15DB.. 20DB.. 25WeightSubplate mountingDB...kg2.6–3.5–4.4DBC...kg1.2DBC 10 or 30 ...kg1.5Threaded connectionDB...Gkg5.35.25.154.8Installation positionanyAmbient temperature rangeNBR seals°C-30 … +80FKM seals°C-15 … +80Minimum stability of the housing materialswith subplate mounting and DBC.. valvesHousing materials are to be selected so that there is sufficient safety for all imaginable operating conditions (e.g. with regard to pressure resistance, thread stripping strengths and tightening torques).hydraulicSize1016252532Maximum operating pressurePort Pbar350Port Xbar350Port Tbar315Maximum counter pressurePort Y (DC solenoid)bar315Minimum set pressureflow-dependent, see characteristic curvesMaximum set pressurebar5010020031535...
generalSize10162532DB.. 15DB.. 20DB.. 25WeightSubplate mountingDBW...kg4.05–4.95–5.85DBWC...kg2.65DBWC 10 or 30 ...kg2.95Threaded connectionDBW...Gkg6.756.656.556.456.25Installation positionanyAmbient temperature rangeNBR seals°C-30 … +50FKM seals°C-15 … +50Minimum stability of the housing materialswith subplate mounting and DBWC.. valvesHousing materials are to be selected so that there is sufficient safety for all imaginable operating conditions (e.g. with regard to pressure resistance, thread stripping strengths and tightening torques).hydraulicSize1016252532Maximum operating pressurePort Pbar350Port Xbar350Port Tbar315Maximum counter pressurePort Y (DC solenoid)bar210Port Y (AC solenoid)bar160Port T (DC solenoid)bar210Port T (AC solenoid)bar160Minimum...
generalSize6Weight (approx.)Type ZDB 6kg1Type Z2DB 6kg1.2Installation positionanyAmbient temperature range°C-20 … +80hydraulicSize6Maximum operating pressurebar315Maximum counter pressure 1)bar315Maximum set pressurebar50100200315Maximum flowl/min60Hydraulic fluidsee tableHydraulic fluid temperature range°C-20 … +80Viscosity rangemm²/s10 … 800Maximum admissible degree of contamination of the hydraulic fluid 2)Class 20/18/15 according to ISO 4406 (c)1)Observe the maximum tank pressure of the subplate-mounted valve/directional valve2)The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components...
generalSize10Weight (approx.)Type ZDBkg2.4Type Z2DBkg2.6Installation positionanyAmbient temperature range°C-20 … +80hydraulicSize10Maximum operating pressurebar315Maximum set pressurebar50100200315Maximum flowl/min100Hydraulic fluidsee tableHydraulic fluid temperature range°C-20 … +80Viscosity rangemm²/s10 … 800Maximum admissible degree of contamination of the hydraulic fluid 1)Class 20/18/15 according to ISO 4406 (c)1)The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.Hydraulic fluidClassificationSuitable sealing materialsStandar...
hydraulicSize102532Maximum operating pressurePort Abar315Port Bbar315Port Xbar315Maximum counter pressurePort Ybar315Minimum set pressureflow-dependent, see characteristic curvesMaximum set pressurebar50100200315Maximum flowl/min200400600Hydraulic fluidsee tableHydraulic fluid temperature rangeNBR seals°C-30 … +80FKM seals°C-20 … +80Viscosity rangemm²/s10 … 800Maximum admissible degree of contamination of the hydraulic fluid 1)Class 20/18/15 according to ISO 4406 (c)1)The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.Hydraulic fl...
generalSize102532WeightType DAkg3.87.713.5Type DA …FSkg4.48.314.1Type DAC …kg1.2Type DAC 30…kg1.4Type DAC 30…FSkg1.9Installation positionanyAmbient temperature rangeNBR seals°C-30 … +80FKM seals°C-20 … +80hydraulicSize102532Maximum operating pressurePort Pbar315Port Abar315 1)Port Tbar100 2) 3)Port Ybar100 2) 3)Set pressure rangePressure rating 50bar25 … 50Pressure rating 100bar50 … 100 4)Pressure rating 200bar100 … 200 4)Pressure rating 315bar200 … 315 5) 4)Switching pressure differentialVersion "FS"freely adjustable (10 % to 50 % of nominal set pressure)Version "10"%10 4)Versi...
generalSize10Weight (approx.)Version "A"kg2.3Version "P"kg2.3Version "B"kg2.7Ambient temperature rangeNBR seals°C-30 … +80FKM seals°C-20 … +80Storage temperature rangeNBR seals°C-30 ... +80FKM seals°C-20 ... +80hydraulicSize10Maximum set pressurebar50100200315Maximum inlet pressurePort A①bar315Port B①bar315Port P②bar315Maximum secondary pressurePort A②bar315Port B②bar315Port P①bar315Maximum counter pressurePort TAbar160Port TBbar160Maximum flowl/min100Hydraulic fluidsee tableHydraulic fluid temperature rangeNBR seals°C-30 … +80FKM seals°C-20 … +80Viscosity rangemm²/s10 … 800Maximum admissible degree of contaminat...
generalSize6Weightkg1.2Installation positionanyStorage temperature rangeNBR seals°C-30 ... +80FKM seal°C-20 ... +80hydraulicSize6Maximum operating pressurePort Pbar315Maximum secondary pressurePort Abar2575150210315Maximum counter pressurePort T (Y)bar160Maximum flowl/min60Hydraulic fluidsee tableHydraulic fluid temperature rangeNBR seals°C-30 … +80FKM seal°C-20 … +80Viscosity rangemm²/s10 … 800Maximum admissible degree of contamination of the hydraulic fluid 1)Class 20/18/15 according to ISO 4406 (c)1)The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For...
generalSize6Weightkg1.2Installation positionanyAmbient temperature rangeNBR seals°C-30 … +80FKM seal°C-20 … +80Storage temperature rangeNBR seals°C-30 ... +80FKM seal°C-20 ... +80Surface protectionStandard: Coating, layer thickness max. 100 µmhydraulicSize6Maximum primary operating pressurebar315Maximum secondary pressure 1)bar2575150210Maximum counter pressurePort Tbar160Maximum flowl/min50Hydraulic fluidMineral oil (HL, HLP) according to DIN 51524; other hydraulic fluids upon request; ignition temperature  180 °CHydraulic fluid temperature rangeNBR seals°C-30 … +80FKM seal°C-20 … +80Viscosity rangemm²/s10 … 800Maximum admissible d...
generalSize10Weight (approx.)kg2.8Installation positionanyAmbient temperature rangeNBR seals°C-30 … +80FKM seal°C-20 … +80hydraulicSize10Maximum operating pressureInletbar315Maximum secondary pressureOutletbar2575150210Maximum counter pressurePort Tbar160Maximum flowl/min80Hydraulic fluidsee tableHydraulic fluid temperature rangeNBR seals°C-30 … +80FKM seal°C-20 … +80Viscosity rangemm²/s10 … 800Maximum admissible degree of contamination of the hydraulic fluid 1)Class 20/18/15 according to ISO 4406 (c)1)The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selec...
generalSize1016252532Type1016 (Typ DR...15)25 (Typ DR..20)25 (Typ DR...25)32 (Typ DR...30)WeightSubplate mountingType DR . .‒kg3.4–5.3–8Cartridge valveType DRCkg1.2Type DRC 30kg1.5Threaded connectionType DR . .Gkg5.35.25.154.8Installation positionanyAmbient temperature rangeNBR seals°C-30 … +50FKM seals°C-20 … +50hydraulicSize10162532Maximum operating pressure 1)Port Bbar350Maximum inlet pressure 1)Port Bbar350Maximum outlet pressure 1)Port …bar350Operating pressure range 1)Port Abar10 … 350Maximum counter pressure 1)Port Ybar350Minimum set pressureflow-dependent, see characteristic curvesMaximum set pressure 1)bar50100200315350Maximum flowSubplate mountingl/min150–300–400Threaded connection...
generalSize10Weightkg6Installation positionanyDirection of flowsee symbolAmbient temperature range°C-30 … +50hydraulicSize10Nominal pressurebar315Maximum operating pressurePort Pbar315Port Abar315Port Yseparate and depressurized to the tankSet pressureMinimumflow-dependent, see characteristic curvesmaximumbar50100200315Maximum flowl/min120Hydraulic fluidsee tableHydraulic fluid temperature rangeNBR seals°C-30 … +80FKM seals°C-20 … +80Viscosity rangemm²/s10 … 800Maximum admissible degree of contamination of the hydraulic fluidClass 9 according to NAS 1638. For this, we recommend using a filter with a minimum retention rate of β10 ≥ 75.Hydraulic fluidClassificationSuitable sealing materialsStandardsMineral oilHL, HLPF...
generalSize2Weightkg0.42Installation positionanyhydraulicSize2Maximum operating pressurebar350Maximum set pressureVersion "C"bar50Version "F"bar100Version "K"bar200Version "R"bar350Maximum admissible return flow pressureMain port ➁ (T)bar200Main port ➃ (Y)bar100 1)Maximum flowl/min140Hydraulic fluidsee tableHydraulic fluid temperature range°C-20 … +80Viscosity rangemm²/s10 … 800Maximum admissible degree of contamination of the hydraulic fluid 2)Class 20/18/15 according to ISO 4406 (c)Load cyclesMio.101)Attention! The applied pressure adds to the set pressure! The switching pressure differential remains unchanged within the setting range!2)The cleanliness classes specified...
14页次1/1HomePrev1NextEnd
回到顶部
Copyright ©2005 - 2017 Siedman (Xiamen)Hydraulic Technology Co;Ltd
犀牛云提供企业云服务